• Certified Reference Materials MTVM

Certified Reference Materials MTVM

  • Mã sản phẩm:

  • Nhà sản xuất: Stanhope-Seta

  • Giá :

    Liên Hệ

Liên hệ đặt hàng:

Certified Reference Materials MTVM

Standard samples SETA MTVM.

FEATURES:

-  Low costs

-  Checking in accordance with the requirements of ASTM / CEN / ISO / IP and equivalent methods of investigation

Incorrect definition of the results may have serious financial costs and create a safety hazard. Increased use of automated equipment increases the possibility that incorrect results may be overlooked; In addition, the timely detection of deviations to minimize the costs associated with "excessive quality" in the sphere of production.

Standard samples, certified by several indicators (MTVM), allow for ongoing monitoring of performance of the device and are particularly useful for training personnel to work on the new equipment and the application of new research methods. We recommend that you purchase these materials together with new equipment to simplify the installation and commissioning of the equipment.

Standard samples MTVM are unique in its kind, because unlike most other certified reference materials that are suitable for testing only what that one parameter or value, they allow the user to inspect the various methods and instruments, using a sample of the same standard .

Standard samples are prepared MTVM major international oil refining company in accordance with ISO 9001 and ISO / IEC / EN 17025 (ISO Regulations 25 and EN 45001) and tested statistically significant number of laboratories to determine the certified values.

Standard samples Seta supplied in containers of 500 ml and have a shelf life of 18 months from the date of delivery.

Note: 
Each sample MTVM has one value for each parameter listed in the table. The actual value obtained during the test shall be within the specified range.

-  AVAILABLE technical data table

-  CERTIFICATE OF COMPLIANCE

99850-0: SETA MTVM - KEROSENE (for gas turbine engines) 500 ml

Name of Test ASTM / Method Range Number / test
Distilling, bubble point D86-IP123; EN ISO 3405 140 - 180 ° C 100 ml
Distillation 10% D86-IP123; EN ISO 3405 159 - 188 ° C 100 ml
Distillation 50% D86-IP123; EN ISO 3405 183 - 218 ° C 100 ml
Distillation 90% D86-IP123; EN ISO 3405 220 - 247 ° C 100 ml
Distillation, boiling point of D86-IP123; EN ISO 3405 244 - 268 ° C 100 ml
The residue after distillation D86-IP123; EN ISO 3405 1.1 - 1.3% volume 100 ml
Losses during distillation D86-IP123; EN ISO 3405 0.4 - 0.8% volume 100 ml
Flash-point IP 170; EN ISO 13736 35 - 60 ° C 85 ml
Congelation point D2386-IP16 from -62 to -44 ° C 25 ml
Aromatic hydrocarbons method FIA D1319-IP156 16 - 22% of the volume 0.75 ml
Maximum smoke point D1322-IP57; ISO 1322 20 - 25 mm 20 ml
Kinematic viscosity at -20 ° C D445-IP71; EN ISO 3104 2 - 8 mm 2 / s 20 ml
Acid number D3242-IP354 <0.100 mg KOH / g 100 ml
Mercaptans D3227-IP342; ISO 3012 0.0001 to 0.01% (m / m) 40 ml

 

99851-0: SETA MTVM - DIESEL 500 ml

Name of Test ASTM / Method Range Number / test
Density at 15 ° C D1298-IP160; EN ISO 3675 0.83 - 0.854 kg / l to 200 ml
Distilling, bubble point D86-IP123; EN ISO 3405 160 - 190 ° C 100 ml
Distillation 10% D86-IP123; EN ISO 3405 200 - 242 ° C 100 ml
Distillation 50% D86-IP123; EN ISO 3405 260 - 290 ° C 100 ml
Distillation 90% D86-IP123; EN ISO 3405 320 - 350 ° C 100 ml
Distillation 95% D86-IP123; EN ISO 3405 335 - 368 ° C 100 ml
Distillation, boiling point of D86-IP123; EN ISO 3405 350 - 385 ° C 100 ml
The residue after distillation D86-IP123; EN ISO 3405 1.25 - 1.42% volume 100 ml
Losses during distillation D86-IP123; EN ISO 3405 0.26 - 0.7% volume 100 ml
Flash-point D93-IP34; EN ISO 2719 56 - 80 ° C 75 ml
Cloud Point D2500; D5771-IP444; D5772-IP445; D5773-IP446; IP219; ISO 3015; EN 23015 from -17 to -4 ° C to 38 ml
Temperature limit of filterability D6317; IP309; EN 1166 from -30 to 0 ° C 45 ml
Pour point D97-IP15; D5950; D5949; D6749;D6892; D5985; EN ISO 3016 from -33 to -6 ° C to 38 ml
Kinematic viscosity at 40 ° C D445-IP71; EN ISO 3104 2.3 - 3.5 mm 2 / s to 40 ml
Lubricity (HFRR) D6079; IP450; ISO 12156-1 271 - 512 micrometers 2 ml
Water content D1744; IP438; EN ISO 12937 23.4 - 63.9 mg / kg 5 ml

 

99854-0: SETA MTVM - motor gasoline 500ml

Name of Test ASTM / Method Range Number / test
Octane motor method D2700; ISO 5163 83 - 90 -
Octane research method D2699; ISO 5164 95 - 101 -
Density at 15 ° C D1298-IP160; EN ISO 3675 0.721 - 0.763 kg / l to 200 ml
Distilling, bubble point D86-IP123; EN ISO 3405 28 - 39 ° C 100 ml
Distillation of 70 ° C D86-IP123; EN ISO 3405 15 - 36% of the volume 100 ml
Distillation 100 ° C D86-IP123; EN ISO 3405 36 - 58% of the volume 100 ml
Distillation 150 ° C D86-IP123; EN ISO 3405 75 - 93% of the volume 100 ml
Distillation, boiling point of D86-IP123; EN ISO 3405 175 - 205 ° C 100 ml
Aromatic hydrocarbons method FIA D1319; IP156 19 - 42% of the volume 0.75 ml
Olefins method FIA D1319; IP156 1.5 - 15% v 0.75 ml
Saturated hydrocarbons, the method of FIA D1319; IP156 42 - 72% of the volume 0.75 ml
Steam pressure D5191; IP394; EN 13016-1 50 - 87 kPa 3 ml

 

99853-0: SETA MTVM - lubricating oil 500 ml

Name of Test ASTM / Method Range Number / test
Kinematic viscosity at 40 ° C D445-IP71; EN ISO 3014 70 - 160 mm 2 / s to 40 ml
Kinematic viscosity at 100 ° C D445-IP71; EN ISO 3014 10 - 19 mm 2 / s to 40 ml
Viscosity index D2270-IP226; To ISO 2909 139 - 180 to 80 ml
Congelation point D97-IP15; D5985; D5950;D5949; D6749; D6892; EN ISO 3016 -49.1 ... -33 ° C to 38 ml
Flash-point D93-IP34; EN ISO 2719 196 - 213 ° C 75 ml

 

99856-0: SETA MTVM - BITUMEN 250 ml

Name of Test ASTM / Method Range Number / test
Softening temperature IP58; EN ISO 1427 37 - 54 ° C 7.5 ml
Penetration IP49; EN ISO 1426 41 - 200 Pen 130 ml

 

99908-0: SETA MTVM - BIOFUELS 500 ml

Name of Test ASTM / Method Range Number / test
Density at 15 ° C D1298-IP160 0.8404 kg / l to 200 ml
Distilling, bubble point D86-IP123 173.6 ° C 100 ml
Distillation 10% D86-IP123 204.7 ° C 100 ml
Distillation 50% D86-IP123 260.7 ° C 100 ml
Distillation 90% D86-IP123 327.2 ° C 100 ml
Distillation 95% D86-IP123 346.2 ° C 100 ml
Distillation, boiling point of D86-IP123 358.1 ° C 100 ml
The bottoms D86-IP123 1.3% volume 100 ml
Losses during distillation D86-IP123 0.6% volume 100 ml
Flash-point D93-IP34 66.6 ° C 75 ml
Cloud Point D2500-IP219 -6.3 ° C to 38 ml
Temperature limit of filterability IP309 -19.7 ° C 45 ml
Congelation point D97-IP15 -28.3 ° C to 38 ml
Kinematic viscosity at 40 ° C D445-IP71 2.567 mm 2 / sec to 40 ml
Lubricity (HFRR) D6079; IP450 207.1 .mu.m 2 ml
Water content D1744; IP438 60,138 mg / kg 5 ml

-   RESEARCH biofuels

99852-0: SETA MTVM - OIL 500 ml

Name of Test ASTM / Method Range Number / test
Density at 15 ° C D1298-IP160; EN ISO 3675 0.94 - 0.994 kg / l to 200 ml
Pour point D97-IP15; D5950; D5949;D6749; D6892; D5985; EN ISO 3016 -14 to 7 ° C to 38 ml
Kinematic viscosity at 50 ° C D445-IP71; EN ISO 3014 150 - 1800 mm 2 / s to 40 ml
Kinematic viscosity at 100 ° C D445-IP71; EN ISO 3014 20 - 95 mm 2 / s to 40 ml
Mikrougrerodisty residue D4530; IP398; ISO 10370 0.1 - 30.0% (m / m) 2 ml
Flash-point D93 (b) -IP34 (b); EN ISO 2719 (b) 92.3 - 121.6 ° C 75 ml

Sản phẩm liên quan

Nhà phân phối

  • omni
  • sigma
  • labconco
  • grant
  • cole
  • labtech
  • buchi
  • Seta
  • Restek