Seta Cloud and Pour Point Cryostat
- Mã sản phẩm: 93531-7
- Nhà sản xuất: Stanhope-Seta
- Giá :
Liên hệ đặt hàng:
Seta Cloud and Pour Point Cryostat
Part Number 93531-7
The Seta Cloud and Pour Point Cryostat has Four 2 litre compartments independently temperature controlled. Three compartments have a temperature range of ambient to -35°C (0 to -35 ±1.5°C). One low temperature compartment -35 to -51°C (±1.5°C). Each 2 litre compartment is individually temperature controlled and can accommodate four Air Wells. The lid is electrically heated to prevent the formation of ice and condensation. Refrigeration is accomplished by a two stage CFC free system. An internal spare canister of R507 refrigerant allows easy recharging of the second stage.
FEATURES
- Four Individually temperature controlled compartments
- Three compartments ambient to -35°
- One compartment -35°C to -51°C
- 2 litre bath capacity in each compartment
- Four air wells in each compartment
- Independent temperature control
- Two stage 'CFC free' refrigeration system
- Heated 'anti-condensation' lid
METHODS
ASTM D2500-IP 219, ASTM D5853-IP 441, ASTM D6422, ASTM D97-IP15, BIS IS 1448 Part 10, BIS IS 1448 Part 110, BS 2000 Parts 15 & 219, EN 23015, FTM 791 201, ISO 3015, ISO 3016
ADDITIONAL INFORMATION
Supplied with: 16 test jars (each comprising graduated glassware, thermometer cork, insulating gasket and disc), a compartment thermometer, and instruction manual.
Note: Due to the low operating temperature of this bath it is recommended that the compartments are filled with Butyl Glycol.
SPECIFICATIONS
Compartment quantity : |
3 + 1 low temperature |
Compartment volume : |
2 litre |
Total test positions : |
16 |
Temperature range : |
Ambient to -35°C (x3) -35°C to -51°C (x1) |
Ambient temperature range : |
15° to 32°C |
Cool down Time (single compartment) : |
approx 2 hrs (from 32°C to -51°C) |
Refrigerant : |
CFC free; First stage R134a; Second stage R507 |
Voltage : |
110/120V, 60Hz 220/240V, 50Hz |
Power : |
1.8kW |
Size (HxWxD) : |
95 x 63 x 63cm |
Weight : |
115kg |
CCCN Code : |
Tariff 90262020 |
DETAILS OF METHODS
BIS IS 1448 Part 10 : |
Cloud Point and Pour Point |
BIS IS 1448 Part 110 : |
Cold Filter Plugging Point of Distillate Fuels |
ASTM D97-IP15 : |
Standard Test Method for Pour Point of Petroleum Products |
ASTM D2500-IP 219 : |
Standard test method for cloud point of petroleum products |
EN 23015 : |
Cloud Point of Petroleum Oils |
BS 2000 Parts 15 & 219 : |
Part 15: Petroleum products. Determination of pour point. Part 219: Determination of cloud point |
ISO 3015 : |
Cloud Point of Petroleum Oils |
ISO 3016 : |
Pour Point of Petroleum Oils |
FTM 791 201 : |
Pour Point of Petroleum Oils |
ASTM D5853-IP 441 : |
Standard test method for pour point of crude oils |
ASTM D6422 : |